nir sensitive cmos camera Search Results


90
Canon inc high-resolution nir sensitive cmos camera canon eos 6d
High Resolution Nir Sensitive Cmos Camera Canon Eos 6d, supplied by Canon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/high-resolution nir sensitive cmos camera canon eos 6d/product/Canon inc
Average 90 stars, based on 1 article reviews
high-resolution nir sensitive cmos camera canon eos 6d - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Swann Communications nir-sensitive camera
Nir Sensitive Camera, supplied by Swann Communications, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/nir-sensitive camera/product/Swann Communications
Average 90 stars, based on 1 article reviews
nir-sensitive camera - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

95
Basler cmos camera
Cmos Camera, supplied by Basler, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/cmos camera/product/Basler
Average 95 stars, based on 1 article reviews
cmos camera - by Bioz Stars, 2026-04
95/100 stars
  Buy from Supplier

95
Basler nir sensitive camera
Nir Sensitive Camera, supplied by Basler, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/nir sensitive camera/product/Basler
Average 95 stars, based on 1 article reviews
nir sensitive camera - by Bioz Stars, 2026-04
95/100 stars
  Buy from Supplier

90
Thermo Fisher evostm m5000 imaging system highly sensitive cmos camera
Evostm M5000 Imaging System Highly Sensitive Cmos Camera, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/evostm m5000 imaging system highly sensitive cmos camera/product/Thermo Fisher
Average 90 stars, based on 1 article reviews
evostm m5000 imaging system highly sensitive cmos camera - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Hamamatsu large-format cmos camera
( a ) Schematic of the ExA-SPIM system. Light enters the system from the laser combiner and is reflected by mirror M1. A cylindrical lens focuses the light in one dimension onto the surface of a tunable lens, which is magnified onto the back focal plane of the excitation through a 1.5×relay consisting of lenses L1 and L2 and mirrors M2 and M3. The excitation objective is oriented vertically and dipped into a liquid immersion chamber. The tunable lens is conjugated to the back focal plane of the excitation objective to enable axial sweeping. A pair of galvo mirrors is used in tandem to translate the position of the light sheet in z (along the optical axis of the detection objective). The detection objective is oriented horizontally. A beam splitter is removed from the lens and replaced with approximately 35 mm of water. A large-format <t>CMOS</t> camera captures images from the detection lens, at a back focusing distance of 50 cm. ( b ) The field of view of the system is 10.6×8.0 mm (13.3 mm diagonal), which is digitized by the camera into a 151-megapixel (MP) image with 0.75 µm/px sampling. Although the optical resolution of the detection lens is ~1.0 µm, the sampling limited resolution based on the Nyquist criterion is ~1.5 µm. The large field of view dramatically reduces the need for tiling. For example, a 3× expanded mouse brain can be captured in only 15 tiles. Representative images of a three expanded mouse brain are shown with a 1 cm scale bar. ( c ) The PSF for 561 nm excitation is shown in the xy , xz , and yz planes. The mean and standard deviation of the lateral and axial full-width half-maximum are shown as a function of x and y position across the full field of view. ( d ) The field curvature and distortion of the system as a function of field position is shown for different wavebands. The field curvature is <2.5× the depth of field (DoF) for all wavebands. This performance is better than ‘Plan’ specified life sciences objectives . ( e ) The relative signal-to-noise ratio (rSNR) of the VP-151MXCMOS camera and an Orca Flash V3 sCMOS camera as a function of imaging speed. The VP-151MX camera provides equivalent SNR at nearly twice the imaging speed.
Large Format Cmos Camera, supplied by Hamamatsu, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/large-format cmos camera/product/Hamamatsu
Average 90 stars, based on 1 article reviews
large-format cmos camera - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Thorlabs high-sensitivity usb 2.0 cmos camera dcc1240c
( a ) Schematic of the ExA-SPIM system. Light enters the system from the laser combiner and is reflected by mirror M1. A cylindrical lens focuses the light in one dimension onto the surface of a tunable lens, which is magnified onto the back focal plane of the excitation through a 1.5×relay consisting of lenses L1 and L2 and mirrors M2 and M3. The excitation objective is oriented vertically and dipped into a liquid immersion chamber. The tunable lens is conjugated to the back focal plane of the excitation objective to enable axial sweeping. A pair of galvo mirrors is used in tandem to translate the position of the light sheet in z (along the optical axis of the detection objective). The detection objective is oriented horizontally. A beam splitter is removed from the lens and replaced with approximately 35 mm of water. A large-format <t>CMOS</t> camera captures images from the detection lens, at a back focusing distance of 50 cm. ( b ) The field of view of the system is 10.6×8.0 mm (13.3 mm diagonal), which is digitized by the camera into a 151-megapixel (MP) image with 0.75 µm/px sampling. Although the optical resolution of the detection lens is ~1.0 µm, the sampling limited resolution based on the Nyquist criterion is ~1.5 µm. The large field of view dramatically reduces the need for tiling. For example, a 3× expanded mouse brain can be captured in only 15 tiles. Representative images of a three expanded mouse brain are shown with a 1 cm scale bar. ( c ) The PSF for 561 nm excitation is shown in the xy , xz , and yz planes. The mean and standard deviation of the lateral and axial full-width half-maximum are shown as a function of x and y position across the full field of view. ( d ) The field curvature and distortion of the system as a function of field position is shown for different wavebands. The field curvature is <2.5× the depth of field (DoF) for all wavebands. This performance is better than ‘Plan’ specified life sciences objectives . ( e ) The relative signal-to-noise ratio (rSNR) of the VP-151MXCMOS camera and an Orca Flash V3 sCMOS camera as a function of imaging speed. The VP-151MX camera provides equivalent SNR at nearly twice the imaging speed.
High Sensitivity Usb 2.0 Cmos Camera Dcc1240c, supplied by Thorlabs, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/high-sensitivity usb 2.0 cmos camera dcc1240c/product/Thorlabs
Average 90 stars, based on 1 article reviews
high-sensitivity usb 2.0 cmos camera dcc1240c - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Thorlabs high-sensitive (cmos) camera
( a ) Schematic of the ExA-SPIM system. Light enters the system from the laser combiner and is reflected by mirror M1. A cylindrical lens focuses the light in one dimension onto the surface of a tunable lens, which is magnified onto the back focal plane of the excitation through a 1.5×relay consisting of lenses L1 and L2 and mirrors M2 and M3. The excitation objective is oriented vertically and dipped into a liquid immersion chamber. The tunable lens is conjugated to the back focal plane of the excitation objective to enable axial sweeping. A pair of galvo mirrors is used in tandem to translate the position of the light sheet in z (along the optical axis of the detection objective). The detection objective is oriented horizontally. A beam splitter is removed from the lens and replaced with approximately 35 mm of water. A large-format <t>CMOS</t> camera captures images from the detection lens, at a back focusing distance of 50 cm. ( b ) The field of view of the system is 10.6×8.0 mm (13.3 mm diagonal), which is digitized by the camera into a 151-megapixel (MP) image with 0.75 µm/px sampling. Although the optical resolution of the detection lens is ~1.0 µm, the sampling limited resolution based on the Nyquist criterion is ~1.5 µm. The large field of view dramatically reduces the need for tiling. For example, a 3× expanded mouse brain can be captured in only 15 tiles. Representative images of a three expanded mouse brain are shown with a 1 cm scale bar. ( c ) The PSF for 561 nm excitation is shown in the xy , xz , and yz planes. The mean and standard deviation of the lateral and axial full-width half-maximum are shown as a function of x and y position across the full field of view. ( d ) The field curvature and distortion of the system as a function of field position is shown for different wavebands. The field curvature is <2.5× the depth of field (DoF) for all wavebands. This performance is better than ‘Plan’ specified life sciences objectives . ( e ) The relative signal-to-noise ratio (rSNR) of the VP-151MXCMOS camera and an Orca Flash V3 sCMOS camera as a function of imaging speed. The VP-151MX camera provides equivalent SNR at nearly twice the imaging speed.
High Sensitive (Cmos) Camera, supplied by Thorlabs, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/high-sensitive (cmos) camera/product/Thorlabs
Average 90 stars, based on 1 article reviews
high-sensitive (cmos) camera - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Hamamatsu orca-flash lt cmos camera
( a ) Schematic of the ExA-SPIM system. Light enters the system from the laser combiner and is reflected by mirror M1. A cylindrical lens focuses the light in one dimension onto the surface of a tunable lens, which is magnified onto the back focal plane of the excitation through a 1.5×relay consisting of lenses L1 and L2 and mirrors M2 and M3. The excitation objective is oriented vertically and dipped into a liquid immersion chamber. The tunable lens is conjugated to the back focal plane of the excitation objective to enable axial sweeping. A pair of galvo mirrors is used in tandem to translate the position of the light sheet in z (along the optical axis of the detection objective). The detection objective is oriented horizontally. A beam splitter is removed from the lens and replaced with approximately 35 mm of water. A large-format <t>CMOS</t> camera captures images from the detection lens, at a back focusing distance of 50 cm. ( b ) The field of view of the system is 10.6×8.0 mm (13.3 mm diagonal), which is digitized by the camera into a 151-megapixel (MP) image with 0.75 µm/px sampling. Although the optical resolution of the detection lens is ~1.0 µm, the sampling limited resolution based on the Nyquist criterion is ~1.5 µm. The large field of view dramatically reduces the need for tiling. For example, a 3× expanded mouse brain can be captured in only 15 tiles. Representative images of a three expanded mouse brain are shown with a 1 cm scale bar. ( c ) The PSF for 561 nm excitation is shown in the xy , xz , and yz planes. The mean and standard deviation of the lateral and axial full-width half-maximum are shown as a function of x and y position across the full field of view. ( d ) The field curvature and distortion of the system as a function of field position is shown for different wavebands. The field curvature is <2.5× the depth of field (DoF) for all wavebands. This performance is better than ‘Plan’ specified life sciences objectives . ( e ) The relative signal-to-noise ratio (rSNR) of the VP-151MXCMOS camera and an Orca Flash V3 sCMOS camera as a function of imaging speed. The VP-151MX camera provides equivalent SNR at nearly twice the imaging speed.
Orca Flash Lt Cmos Camera, supplied by Hamamatsu, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/orca-flash lt cmos camera/product/Hamamatsu
Average 90 stars, based on 1 article reviews
orca-flash lt cmos camera - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Prosilica Inc near-infrared (nir) sensitive ccd video camera
( a ) Schematic of the ExA-SPIM system. Light enters the system from the laser combiner and is reflected by mirror M1. A cylindrical lens focuses the light in one dimension onto the surface of a tunable lens, which is magnified onto the back focal plane of the excitation through a 1.5×relay consisting of lenses L1 and L2 and mirrors M2 and M3. The excitation objective is oriented vertically and dipped into a liquid immersion chamber. The tunable lens is conjugated to the back focal plane of the excitation objective to enable axial sweeping. A pair of galvo mirrors is used in tandem to translate the position of the light sheet in z (along the optical axis of the detection objective). The detection objective is oriented horizontally. A beam splitter is removed from the lens and replaced with approximately 35 mm of water. A large-format <t>CMOS</t> camera captures images from the detection lens, at a back focusing distance of 50 cm. ( b ) The field of view of the system is 10.6×8.0 mm (13.3 mm diagonal), which is digitized by the camera into a 151-megapixel (MP) image with 0.75 µm/px sampling. Although the optical resolution of the detection lens is ~1.0 µm, the sampling limited resolution based on the Nyquist criterion is ~1.5 µm. The large field of view dramatically reduces the need for tiling. For example, a 3× expanded mouse brain can be captured in only 15 tiles. Representative images of a three expanded mouse brain are shown with a 1 cm scale bar. ( c ) The PSF for 561 nm excitation is shown in the xy , xz , and yz planes. The mean and standard deviation of the lateral and axial full-width half-maximum are shown as a function of x and y position across the full field of view. ( d ) The field curvature and distortion of the system as a function of field position is shown for different wavebands. The field curvature is <2.5× the depth of field (DoF) for all wavebands. This performance is better than ‘Plan’ specified life sciences objectives . ( e ) The relative signal-to-noise ratio (rSNR) of the VP-151MXCMOS camera and an Orca Flash V3 sCMOS camera as a function of imaging speed. The VP-151MX camera provides equivalent SNR at nearly twice the imaging speed.
Near Infrared (Nir) Sensitive Ccd Video Camera, supplied by Prosilica Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/near-infrared (nir) sensitive ccd video camera/product/Prosilica Inc
Average 90 stars, based on 1 article reviews
near-infrared (nir) sensitive ccd video camera - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Hamamatsu nir sensitive streak camera
( a ) Schematic of the ExA-SPIM system. Light enters the system from the laser combiner and is reflected by mirror M1. A cylindrical lens focuses the light in one dimension onto the surface of a tunable lens, which is magnified onto the back focal plane of the excitation through a 1.5×relay consisting of lenses L1 and L2 and mirrors M2 and M3. The excitation objective is oriented vertically and dipped into a liquid immersion chamber. The tunable lens is conjugated to the back focal plane of the excitation objective to enable axial sweeping. A pair of galvo mirrors is used in tandem to translate the position of the light sheet in z (along the optical axis of the detection objective). The detection objective is oriented horizontally. A beam splitter is removed from the lens and replaced with approximately 35 mm of water. A large-format <t>CMOS</t> camera captures images from the detection lens, at a back focusing distance of 50 cm. ( b ) The field of view of the system is 10.6×8.0 mm (13.3 mm diagonal), which is digitized by the camera into a 151-megapixel (MP) image with 0.75 µm/px sampling. Although the optical resolution of the detection lens is ~1.0 µm, the sampling limited resolution based on the Nyquist criterion is ~1.5 µm. The large field of view dramatically reduces the need for tiling. For example, a 3× expanded mouse brain can be captured in only 15 tiles. Representative images of a three expanded mouse brain are shown with a 1 cm scale bar. ( c ) The PSF for 561 nm excitation is shown in the xy , xz , and yz planes. The mean and standard deviation of the lateral and axial full-width half-maximum are shown as a function of x and y position across the full field of view. ( d ) The field curvature and distortion of the system as a function of field position is shown for different wavebands. The field curvature is <2.5× the depth of field (DoF) for all wavebands. This performance is better than ‘Plan’ specified life sciences objectives . ( e ) The relative signal-to-noise ratio (rSNR) of the VP-151MXCMOS camera and an Orca Flash V3 sCMOS camera as a function of imaging speed. The VP-151MX camera provides equivalent SNR at nearly twice the imaging speed.
Nir Sensitive Streak Camera, supplied by Hamamatsu, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/nir sensitive streak camera/product/Hamamatsu
Average 90 stars, based on 1 article reviews
nir sensitive streak camera - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Hamamatsu high-sensitivity camera scientific cmos sensor
( a ) Schematic of the ExA-SPIM system. Light enters the system from the laser combiner and is reflected by mirror M1. A cylindrical lens focuses the light in one dimension onto the surface of a tunable lens, which is magnified onto the back focal plane of the excitation through a 1.5×relay consisting of lenses L1 and L2 and mirrors M2 and M3. The excitation objective is oriented vertically and dipped into a liquid immersion chamber. The tunable lens is conjugated to the back focal plane of the excitation objective to enable axial sweeping. A pair of galvo mirrors is used in tandem to translate the position of the light sheet in z (along the optical axis of the detection objective). The detection objective is oriented horizontally. A beam splitter is removed from the lens and replaced with approximately 35 mm of water. A large-format <t>CMOS</t> camera captures images from the detection lens, at a back focusing distance of 50 cm. ( b ) The field of view of the system is 10.6×8.0 mm (13.3 mm diagonal), which is digitized by the camera into a 151-megapixel (MP) image with 0.75 µm/px sampling. Although the optical resolution of the detection lens is ~1.0 µm, the sampling limited resolution based on the Nyquist criterion is ~1.5 µm. The large field of view dramatically reduces the need for tiling. For example, a 3× expanded mouse brain can be captured in only 15 tiles. Representative images of a three expanded mouse brain are shown with a 1 cm scale bar. ( c ) The PSF for 561 nm excitation is shown in the xy , xz , and yz planes. The mean and standard deviation of the lateral and axial full-width half-maximum are shown as a function of x and y position across the full field of view. ( d ) The field curvature and distortion of the system as a function of field position is shown for different wavebands. The field curvature is <2.5× the depth of field (DoF) for all wavebands. This performance is better than ‘Plan’ specified life sciences objectives . ( e ) The relative signal-to-noise ratio (rSNR) of the VP-151MXCMOS camera and an Orca Flash V3 sCMOS camera as a function of imaging speed. The VP-151MX camera provides equivalent SNR at nearly twice the imaging speed.
High Sensitivity Camera Scientific Cmos Sensor, supplied by Hamamatsu, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/high-sensitivity camera scientific cmos sensor/product/Hamamatsu
Average 90 stars, based on 1 article reviews
high-sensitivity camera scientific cmos sensor - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

Image Search Results


( a ) Schematic of the ExA-SPIM system. Light enters the system from the laser combiner and is reflected by mirror M1. A cylindrical lens focuses the light in one dimension onto the surface of a tunable lens, which is magnified onto the back focal plane of the excitation through a 1.5×relay consisting of lenses L1 and L2 and mirrors M2 and M3. The excitation objective is oriented vertically and dipped into a liquid immersion chamber. The tunable lens is conjugated to the back focal plane of the excitation objective to enable axial sweeping. A pair of galvo mirrors is used in tandem to translate the position of the light sheet in z (along the optical axis of the detection objective). The detection objective is oriented horizontally. A beam splitter is removed from the lens and replaced with approximately 35 mm of water. A large-format CMOS camera captures images from the detection lens, at a back focusing distance of 50 cm. ( b ) The field of view of the system is 10.6×8.0 mm (13.3 mm diagonal), which is digitized by the camera into a 151-megapixel (MP) image with 0.75 µm/px sampling. Although the optical resolution of the detection lens is ~1.0 µm, the sampling limited resolution based on the Nyquist criterion is ~1.5 µm. The large field of view dramatically reduces the need for tiling. For example, a 3× expanded mouse brain can be captured in only 15 tiles. Representative images of a three expanded mouse brain are shown with a 1 cm scale bar. ( c ) The PSF for 561 nm excitation is shown in the xy , xz , and yz planes. The mean and standard deviation of the lateral and axial full-width half-maximum are shown as a function of x and y position across the full field of view. ( d ) The field curvature and distortion of the system as a function of field position is shown for different wavebands. The field curvature is <2.5× the depth of field (DoF) for all wavebands. This performance is better than ‘Plan’ specified life sciences objectives . ( e ) The relative signal-to-noise ratio (rSNR) of the VP-151MXCMOS camera and an Orca Flash V3 sCMOS camera as a function of imaging speed. The VP-151MX camera provides equivalent SNR at nearly twice the imaging speed.

Journal: eLife

Article Title: Expansion-assisted selective plane illumination microscopy for nanoscale imaging of centimeter-scale tissues

doi: 10.7554/eLife.91979

Figure Lengend Snippet: ( a ) Schematic of the ExA-SPIM system. Light enters the system from the laser combiner and is reflected by mirror M1. A cylindrical lens focuses the light in one dimension onto the surface of a tunable lens, which is magnified onto the back focal plane of the excitation through a 1.5×relay consisting of lenses L1 and L2 and mirrors M2 and M3. The excitation objective is oriented vertically and dipped into a liquid immersion chamber. The tunable lens is conjugated to the back focal plane of the excitation objective to enable axial sweeping. A pair of galvo mirrors is used in tandem to translate the position of the light sheet in z (along the optical axis of the detection objective). The detection objective is oriented horizontally. A beam splitter is removed from the lens and replaced with approximately 35 mm of water. A large-format CMOS camera captures images from the detection lens, at a back focusing distance of 50 cm. ( b ) The field of view of the system is 10.6×8.0 mm (13.3 mm diagonal), which is digitized by the camera into a 151-megapixel (MP) image with 0.75 µm/px sampling. Although the optical resolution of the detection lens is ~1.0 µm, the sampling limited resolution based on the Nyquist criterion is ~1.5 µm. The large field of view dramatically reduces the need for tiling. For example, a 3× expanded mouse brain can be captured in only 15 tiles. Representative images of a three expanded mouse brain are shown with a 1 cm scale bar. ( c ) The PSF for 561 nm excitation is shown in the xy , xz , and yz planes. The mean and standard deviation of the lateral and axial full-width half-maximum are shown as a function of x and y position across the full field of view. ( d ) The field curvature and distortion of the system as a function of field position is shown for different wavebands. The field curvature is <2.5× the depth of field (DoF) for all wavebands. This performance is better than ‘Plan’ specified life sciences objectives . ( e ) The relative signal-to-noise ratio (rSNR) of the VP-151MXCMOS camera and an Orca Flash V3 sCMOS camera as a function of imaging speed. The VP-151MX camera provides equivalent SNR at nearly twice the imaging speed.

Article Snippet: A bead phantom (see point spread function measurement) was used to compare the sensitivity of the large-format CMOS camera and a scientific CMOS camera (Orca Flash V3, Hamamatsu).

Techniques: Sampling, Standard Deviation, Imaging

( a–c ) A traditional cleared-tissue SPIM system uses standard 100 mW or less lasers, a scientific CMOS camera, and life sciences objectives with higher NA and <10 mm working distance. In theory, these systems can image an entire cleared mouse brain at 500 nm or less resolution without any physical cutting. However, this would require 400+ individual image tiles and high camera framerates, which is problematic for techniques such as axial sweeping. (bd) By comparison, the ExA-SPIM system uses 1000+ mW lasers, a large-format CMOS camera, and electronics metrology lenses with a moderate NA and ~35 mm working distance. After expanding a mouse brain 3×, the system is still capable of imaging the entire brain in only 15 tiles.

Journal: eLife

Article Title: Expansion-assisted selective plane illumination microscopy for nanoscale imaging of centimeter-scale tissues

doi: 10.7554/eLife.91979

Figure Lengend Snippet: ( a–c ) A traditional cleared-tissue SPIM system uses standard 100 mW or less lasers, a scientific CMOS camera, and life sciences objectives with higher NA and <10 mm working distance. In theory, these systems can image an entire cleared mouse brain at 500 nm or less resolution without any physical cutting. However, this would require 400+ individual image tiles and high camera framerates, which is problematic for techniques such as axial sweeping. (bd) By comparison, the ExA-SPIM system uses 1000+ mW lasers, a large-format CMOS camera, and electronics metrology lenses with a moderate NA and ~35 mm working distance. After expanding a mouse brain 3×, the system is still capable of imaging the entire brain in only 15 tiles.

Article Snippet: A bead phantom (see point spread function measurement) was used to compare the sensitivity of the large-format CMOS camera and a scientific CMOS camera (Orca Flash V3, Hamamatsu).

Techniques: Comparison, Imaging